TEFMA Elettromeccanica in Veggiano designs and manufactures single-phase transformers that operate with a single-phase power supply circuit. They receive power from a single-phase power source, such as that supplied by household outlets.
Usually equipped with two windings, one called "primary" and the other "secondary," single-phase transformers play a crucial role in power distribution. The primary winding is connected to the single-phase power source and receives the input voltage, while the secondary winding provides the transformed voltage at the output to power connected devices. Widely used in various applications, including electronic equipment, power supplies, control devices, and electric lighting, single-phase transformers are available in different sizes, power ratings, and configurations to suit specific application needs. Contact us to discover all possible configurations and find the ideal solution for your project.
General specifications:
The 10W - 20W - 40W models are supplied in BLACK colour.
Series Voltage: (IN) 230 Volt Primary Voltage (OUT) 12 Volt Secondary Voltage.
Upon request, primary and secondary voltages can be adjusted according to usage.
Test Voltage: 3000 Volt.
Mod. 10W - PTC protection 190 mA on the primary.
Mod. 20W - Thermal protection 80° on the primary.
Mod. 40W - Thermal protection 90° on the primary.
The Transformers are encapsulated in self-extinguishing resin Class E, and built according to the CEI 96-2 EN 60742 standards.
EMC test reports have been conducted on the aforementioned Transformers, emission measurements: Radiated - Conducted - Harmonics.
General specifications:
Series Voltage: 0 - 230 - 400 / 24 with intermediate flange and protective brackets.
Test Voltage 3 kV/50Hz.
The measurement (X) minimum cannot always be guaranteed in all models. Voltages in input or output depending on use. Weights are indicative.
The dimensions of the footprint and fastening may vary depending on the special voltages required.
General specifications:
Series Voltage: 115/230V - 230/400 V
Special models available with any Voltage.
The footprint dimensions may vary depending on the special voltages required.
General specifications:
Transformers built according to EN-60742 standards.
Insulation class t.a. 40° /E
IP00 protection rating
Test voltage 3 kV
The size and weight are significantly reduced compared to traditional transformers.
Upon request, they can be provided with:
- Thermal protection 90° on the primary,
- Plastic enclosure,
- Power and voltages according to usage
General specifications:
Series Voltage: 115/230V - 230/400 V
Special models available with any Voltage.
The footprint dimensions may vary depending on the special voltages required.
Via Alessandro Volta 17
35030 Veggiano (PD)